Re: [PATCH v2 1/1] dt-bindings: iio: pressure: Support Honeywell mprls0025pa sensor
From: Krzysztof Kozlowski
Date: Fri Apr 14 2023 - 16:42:43 EST
On 14/04/2023 22:40, Krzysztof Kozlowski wrote:
> On 14/04/2023 14:48, Andreas Klinger wrote:
>> Honeywell mpr is a pressure sensor series. There are many different models with different pressure
>> ranges, units and transfer functions.
>>
>> The range and transfer function need to be set up in the dt. Therefore new properties
>> honeywell,pmin-pascal, honeywell,pmax-pascal, honeywell,transfer-function are introduced.
>
> Please wrap commit message according to Linux coding style / submission
> process (neither too early nor over the limit):
> https://elixir.bootlin.com/linux/v5.18-rc4/source/Documentation/process/submitting-patches.rst#L586
>
>>
>> Add dt-bindings.
>>
>> Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx>
>
> Patches 2 and 3 are missing. At least they were mentioned in the
> changelog but this is 1/1.
>
>> ---
>> .../iio/pressure/honeywell,mprls0025pa.yaml | 93 +++++++++++++++++++
>> 1 file changed, 93 insertions(+)
>> create mode 100644 Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
>>
>> diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
>> new file mode 100644
>> index 000000000000..c0eb3c4be16f
>> --- /dev/null
>> +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
>> @@ -0,0 +1,93 @@
>> +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
>> +%YAML 1.2
>> +---
>> +$id: http://devicetree.org/schemas/iio/pressure/honeywell,mprls0025pa.yaml#
>> +$schema: http://devicetree.org/meta-schemas/core.yaml#
>> +
>> +title: Honeywell mpr series pressure sensor
>> +
>> +maintainers:
>> + - Andreas Klinger <ak@xxxxxxxxxxxxx>
>> +
>> +description: |
>> + Honeywell pressure sensor of model mprls0025pa.
>> +
>> + This sensor has an I2C and SPI interface. Only the I2C interface is implemented.
>> +
>> + There are many models with different pressure ranges available. The vendor calls them "mpr
>> + series". All of them have the identical programming model and differ in the pressure range, unit
>
> Wrap according to Linux coding style, so at 80.
>
>> + and transfer function.
>> +
>> + To support different models one need to specify the pressure range as well as the transfer
>> + function. Pressure range needs to be converted from its unit to pascal.
>> +
>> + The transfer function defines the ranges of numerical values delivered by the sensor. The minimal
>> + range value stands for the minimum pressure and the maximum value also for the maximum pressure
>> + with linear relation inside the range.
>> +
>> + Specifications about the devices can be found at:
>> + https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/
>> + pressure-sensors/board-mount-pressure-sensors/micropressure-mpr-series/documents/
>> + sps-siot-mpr-series-datasheet-32332628-ciid-172626.pdf
>> +
>> +properties:
>> + compatible:
>> + const: honeywell,mprls0025pa
>
> So this is one compatible for entire family of 96 separate devices.
> Looks like reasonable compromise, although I will wait for Rob's
> approval on that.
>
> Anyway you need to fix the coding style.
... and as Rob's bot pointed out, test it before sending.
Best regards,
Krzysztof