Re: [PATCH] dt-bindings: thermal: qcom-tsens: correct unit address
From: Konrad Dybcio
Date: Thu Apr 20 2023 - 06:42:45 EST
On 20.04.2023 09:24, Krzysztof Kozlowski wrote:
> Match unit-address to first reg entry.
>
> Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
> ---
Reviewed-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxx>
Konrad
> Documentation/devicetree/bindings/thermal/qcom-tsens.yaml | 4 ++--
> 1 file changed, 2 insertions(+), 2 deletions(-)
>
> diff --git a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
> index b6452ed78802..d9aa54c11663 100644
> --- a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
> +++ b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
> @@ -328,7 +328,7 @@ examples:
> - |
> #include <dt-bindings/interrupt-controller/arm-gic.h>
> // Example 1 (new calbiration data: for pre v1 IP):
> - thermal-sensor@900000 {
> + thermal-sensor@4a9000 {
> compatible = "qcom,msm8916-tsens", "qcom,tsens-v0_1";
> reg = <0x4a9000 0x1000>, /* TM */
> <0x4a8000 0x1000>; /* SROT */
> @@ -358,7 +358,7 @@ examples:
> - |
> #include <dt-bindings/interrupt-controller/arm-gic.h>
> // Example 1 (legacy: for pre v1 IP):
> - tsens1: thermal-sensor@900000 {
> + tsens1: thermal-sensor@4a9000 {
> compatible = "qcom,msm8916-tsens", "qcom,tsens-v0_1";
> reg = <0x4a9000 0x1000>, /* TM */
> <0x4a8000 0x1000>; /* SROT */