Re: [PATCH v7 0/3] dsa: marvell: Add support for mv88e6071 and 6020 switches
From: Andrew Lunn
Date: Wed May 24 2023 - 09:48:19 EST
> > Vladimir indicates here that it is not known how to change the max MTU
> > for the MV88E6250. Where did you get the information from to implement
> > it?
>
> Please refer to [1].
>
> The mv88e6185_g1_set_max_frame_size() function can be reused (as
> registers' offsets and bits are the same for mv88e60{71|20}).
So you have the datasheet? You get the information to implement this
from the data sheet?
Andrew