[PATCH] pwm: meson: compute cnt register value in proper way
From: George Stark
Date: Fri Jun 02 2023 - 06:35:41 EST
According to the datasheet, the PWM high and low clock count values
should be set to at least one. Therefore, setting the clock count
register to 0 actually means 1 clock count.
Signed-off-by: George Stark <GNStark@xxxxxxxxxxxxxx>
Signed-off-by: Dmitry Rokosov <ddrokosov@xxxxxxxxxxxxxx>
---
This patch is based on currently unmerged patch by Heiner Kallweit
https://lore.kernel.org/linux-amlogic/23fe625e-dc23-4db8-3dce-83167cd3b206@xxxxxxxxx
---
diff --git a/drivers/pwm/pwm-meson.c b/drivers/pwm/pwm-meson.c
index 834acd7..57e7d9c 100644
--- a/drivers/pwm/pwm-meson.c
+++ b/drivers/pwm/pwm-meson.c
@@ -206,6 +206,11 @@
channel->pre_div = pre_div;
channel->hi = duty_cnt;
channel->lo = cnt - duty_cnt;
+
+ if (channel->hi)
+ channel->hi--;
+ if (channel->lo)
+ channel->lo--;
}
return 0;
@@ -340,7 +345,8 @@
channel->lo = FIELD_GET(PWM_LOW_MASK, value);
channel->hi = FIELD_GET(PWM_HIGH_MASK, value);
- state->period = meson_pwm_cnt_to_ns(chip, pwm, channel->lo + channel->hi);
+ state->period = meson_pwm_cnt_to_ns(chip, pwm,
+ channel->lo + 1 + channel->hi + 1);
state->duty_cycle = meson_pwm_cnt_to_ns(chip, pwm, channel->hi);
return 0;