[PATCH blktests v1 1/3] nvme/048: Check for queue count check directly

From: Daniel Wagner
Date: Tue Jun 20 2023 - 09:27:24 EST


The test monitored the state changes live -> resetting -> connecting ->
live, to figure out the queue count change was successful.

The fc transport is reconnecting very fast and the state transitions
are not observed by the current approach.

So instead trying to monitor the state changes, let's just wait for the
live state and the correct queue number.

As queue count is depending on the number of online CPUs we explicitly
use 1 and 2 for the max_queue count. This means the queue_count value
needs to reach either 2 or 3 (admin queue included).

Signed-off-by: Daniel Wagner <dwagner@xxxxxxx>
---
tests/nvme/048 | 35 ++++++++++++++++++++++++-----------
1 file changed, 24 insertions(+), 11 deletions(-)

diff --git a/tests/nvme/048 b/tests/nvme/048
index 81084f0440c2..3dc5169132de 100755
--- a/tests/nvme/048
+++ b/tests/nvme/048
@@ -42,6 +42,26 @@ nvmf_wait_for_state() {
return 0
}

+nvmf_wait_for_queue_count() {
+ local subsys_name="$1"
+ local queue_count="$2"
+ local nvmedev
+
+ nvmedev=$(_find_nvme_dev "${subsys_name}")
+
+ queue_count_file="/sys/class/nvme-fabrics/ctl/${nvmedev}/queue_count"
+
+ nvmf_wait_for_state "${subsys_name}" "live" || return 1
+
+ queue_count=$((queue_count + 1))
+ if grep -q "${queue_count}" "${queue_count_file}"; then
+ return 0
+ fi
+
+ echo "expected queue count ${queue_count} not set"
+ return 1
+}
+
set_nvmet_attr_qid_max() {
local nvmet_subsystem="$1"
local qid_max="$2"
@@ -56,10 +76,7 @@ set_qid_max() {
local qid_max="$3"

set_nvmet_attr_qid_max "${subsys_name}" "${qid_max}"
-
- # Setting qid_max forces a disconnect and the reconntect attempt starts
- nvmf_wait_for_state "${subsys_name}" "connecting" || return 1
- nvmf_wait_for_state "${subsys_name}" "live" || return 1
+ nvmf_wait_for_queue_count "${subsys_name}" "${qid_max}" || return 1

return 0
}
@@ -77,12 +94,8 @@ test() {

_setup_nvmet

- hostid="$(uuidgen)"
- if [ -z "$hostid" ] ; then
- echo "uuidgen failed"
- return 1
- fi
- hostnqn="nqn.2014-08.org.nvmexpress:uuid:${hostid}"
+ hostid="${def_hostid}"
+ hostnqn="${def_hostnqn}"

truncate -s "${nvme_img_size}" "${file_path}"

@@ -103,7 +116,7 @@ test() {
echo FAIL
else
set_qid_max "${port}" "${subsys_name}" 1 || echo FAIL
- set_qid_max "${port}" "${subsys_name}" 128 || echo FAIL
+ set_qid_max "${port}" "${subsys_name}" 2 || echo FAIL
fi

_nvme_disconnect_subsys "${subsys_name}"
--
2.41.0