[PATCH 1/1] thermal: sysfs: avoid actual readings from sysfs
From: Eduardo Valentin
Date: Fri Jun 30 2023 - 21:39:04 EST
Hey Daniel,
On Fri, Jun 30, 2023 at 12:11:25PM +0200, Daniel Lezcano wrote:
>
>
>
> Hi Rafael,
>
> On 30/06/2023 10:16, Rafael J. Wysocki wrote:
> > On Wed, Jun 28, 2023 at 11:10 PM Eduardo Valentin <evalenti@xxxxxxxxxx> wrote:
>
> [ ... ]
>
> > So what about adding a new zone attribute that can be used to specify
> > the preferred caching time for the temperature?
> >
> > That is, if the time interval between two consecutive updates of the
> > cached temperature value is less than the value of the new attribute,
> > the cached temperature value will be returned by "temp". Otherwise,
> > it will cause the sensor to be read and the value obtained from it
> > will be returned to user space and cached.
> >
> > If the value of the new attribute is 0, everything will work as it
> > does now (which will also need to be the default behavior).
>
> I'm still not convinced about the feature.
>
> Eduardo provided some numbers but they seem based on the characteristics
> of the I2C, not to a real use case. Eduardo?
Why I2C is not a real use case?
--
All the best,
Eduardo Valentin