Re: [PATCH 1/1] thermal/drivers/imx_sc_thermal: return -EAGAIN when SCFW turn off resource

From: Frank Li
Date: Fri Jul 14 2023 - 13:19:49 EST


On Thu, Jul 13, 2023 at 02:49:54PM +0200, Daniel Lezcano wrote:
> On 12/07/2023 23:05, Frank Li wrote:
> > Avoid endless print following message when SCFW turns off resource.
> > [ 1818.342337] thermal thermal_zone0: failed to read out thermal zone (-1)
> >
> > Signed-off-by: Frank Li <Frank.Li@xxxxxxx>
> > ---
> > drivers/thermal/imx_sc_thermal.c | 4 +++-
> > 1 file changed, 3 insertions(+), 1 deletion(-)
> >
> > diff --git a/drivers/thermal/imx_sc_thermal.c b/drivers/thermal/imx_sc_thermal.c
> > index 8d6b4ef23746..0533d58f199f 100644
> > --- a/drivers/thermal/imx_sc_thermal.c
> > +++ b/drivers/thermal/imx_sc_thermal.c
> > @@ -58,7 +58,9 @@ static int imx_sc_thermal_get_temp(struct thermal_zone_device *tz, int *temp)
> > hdr->size = 2;
> > ret = imx_scu_call_rpc(thermal_ipc_handle, &msg, true);
> > - if (ret)
> > + if (ret == -EPERM) /* NO POWER */
> > + return -EAGAIN;
>
> Isn't there a chain call somewhere when the resource is turned off, so the
> thermal zone can be disabled?

A possible place in drivers/firmware/imx/scu-pd.c. but I am not sure how to
get thermal devices. I just found a API thermal_zone_get_zone_by_name(). I
am not sure if it is good to depend on "name", which add coupling between
two drivers and if there are external thermal devices(such as) has the
same name, it will wrong turn off.

If add power domain notification in thermal driver, I am not how to get
other devices's pd in thermal driver.

Any example I can refer?

Or this is simple enough solution.

Frank

>
> > + else if (ret)
> > return ret;
> > *temp = msg.data.resp.celsius * 1000 + msg.data.resp.tenths * 100;
>
> --
> <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs
>
> Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook |
> <http://twitter.com/#!/linaroorg> Twitter |
> <http://www.linaro.org/linaro-blog/> Blog
>