Re: [PATCH 3/3] tick/nohz: Don't shutdown the lowres tick from itself

From: Joel Fernandes
Date: Sat Jul 15 2023 - 18:31:43 EST




> On Jul 15, 2023, at 2:19 PM, Frederic Weisbecker <frederic@xxxxxxxxxx> wrote:
>
> On Fri, Jul 14, 2023 at 09:02:43PM -0400, Joel Fernandes wrote:
>>> On Fri, Jul 14, 2023 at 8:01 PM Frederic Weisbecker <frederic@xxxxxxxxxx> wrote:
>>>
>>> On Fri, Jul 14, 2023 at 02:44:49PM -0400, Joel Fernandes wrote:
>>>> On 7/14/23 08:08, Frederic Weisbecker wrote:
>>>> One slight concern here though, where in the idle loop is the removed
>>>> statement "tick_program_event(KTIME_MAX, 1);" happening if the tick was
>>>> already stopped before? If it is happening in tick_nohz_stop_tick(), don't
>>>> we early return from there and avoid doing that
>>>> "tick_program_event(KTIME_MAX, 1);" altogether, if the tick was already
>>>> stopped and the next event has not changed?
>>>>
>>>> /* Skip reprogram of event if its not changed */
>>>> if (ts->tick_stopped && (expires == ts->next_tick)) {
>>>> /* Sanity check: make sure clockevent is actually programmed */
>>>> if (tick == KTIME_MAX || ts->next_tick == [...]
>>>> return;
>>>> [...]
>>>> }
>>>
>>> Sure, if tick_program_event(KTIME_MAX, 1) was already called in the
>>> previous idle loop iteration, then there is no need to call that again.
>>>
>>> Or am I missing something else?
>>
>> Just take it with a grain of salt but I think you need to still call
>> tick_program_event(KTIME_MAX, 1) here for the case where the tick was
>> previously stopped, and then when the next tick fires (say after a
>> long time T), but that tick is a one-off and does not result in
>> restarting the tick -- then there is no one to call
>> "tick_program_event(KTIME_MAX, 1)".
>
> I'm a bit confused about that one-off thing. What can trigger that timer
> interrupt if it has been stopped?

It is the tick that has been stopped in this scenario.
The timer could still be armed to serve a future hrtimer?

I think the naming in the code for is a bit confusing for tick vs timer event,
so I could be the confused one.

Thanks,

- Joel


> One thing can happen though: a pending timer IRQ while we are stopping the
> tick (IRQs are disabled in that idle loop portion). But then that pending timer
> interrupt is not going to reprogram another one. So it remains stopped.
>
> Thanks.