Re: [PATCH v13 03/10] dt-bindings: opp: v2-qcom-level: Document CPR3 open/closed loop volt adjustment
From: Krzysztof Kozlowski
Date: Tue Aug 08 2023 - 13:41:52 EST
On 02/08/2023 14:37, Konrad Dybcio wrote:
> CPR3 and newer can be fed per-OPP voltage adjustment values for both
> open- and closed-loop paths to make better decisions about settling
> on the final voltage offset target. Document these properties.
>
> Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>
> Tested-by: Jeffrey Hugo <quic_jhugo@xxxxxxxxxxx>
> Signed-off-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxx>
> ---
> .../devicetree/bindings/opp/opp-v2-qcom-level.yaml | 14 ++++++++++++++
> 1 file changed, 14 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml b/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml
> index a30ef93213c0..b203ea01b17a 100644
> --- a/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml
> +++ b/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml
> @@ -34,6 +34,20 @@ patternProperties:
> minItems: 1
> maxItems: 2
>
> + qcom,opp-cloop-vadj:
> + description: |
> + An array of per-thread values representing the closed-loop
> + voltage adjustment value associated with this OPP node.
> + $ref: /schemas/types.yaml#/definitions/int32-array
I assume negative values are accepted on purpose.
Adding these to example would be useful. Anyway:
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
Best regards,
Krzysztof