Re: [PATCH v3] hwmon: (aquacomputer_d5next) Add selective 200ms delay after sending ctrl report

From: Guenter Roeck
Date: Thu Aug 10 2023 - 00:09:19 EST


On Mon, Aug 07, 2023 at 07:20:03PM +0200, Aleksa Savic wrote:
> Add a 200ms delay after sending a ctrl report to Quadro,
> Octo, D5 Next and Aquaero to give them enough time to
> process the request and save the data to memory. Otherwise,
> under heavier userspace loads where multiple sysfs entries
> are usually set in quick succession, a new ctrl report could
> be requested from the device while it's still processing the
> previous one and fail with -EPIPE. The delay is only applied
> if two ctrl report operations are near each other in time.
>
> Reported by a user on Github [1] and tested by both of us.
>
> [1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/82
>
> Fixes: 752b927951ea ("hwmon: (aquacomputer_d5next) Add support for Aquacomputer Octo")
> Signed-off-by: Aleksa Savic <savicaleksa83@xxxxxxxxx>

I would have suggested to use fsleep() to avoid unnecessary
sleep times if they are small, bt I guess it doesn't make much
of a difference.

Applied.

Thanks,
Guenter