[PATCH v2] clk: ralink: mtmips: quiet unused variable warning
From: Sergio Paracuellos
Date: Sat Aug 26 2023 - 22:40:16 EST
When CONFIG_OF is disabled then the matching table is not referenced and
the following warning appears:
drivers/clk/ralink/clk-mtmips.c:821:34: warning: unused variable 'mtmips_of_match' [-Wunused-const-variable]
821 | static const struct of_device_id mtmips_of_match[] = {
| ^
There are two match tables in the driver: one for the clock driver and the
other for the reset driver. The only difference between them is that the
clock driver uses 'data' and does not have 'ralink,rt2880-reset' compatible.
Both just can be merged into a single one just by adding the compatible
'ralink,rt2880-reset' entry to 'mtmips_of_match[]', which will allow it to
be used for 'mtmips_clk_driver' (which doesn't use the data) as well as for
'mtmips_clk_init()' (which doesn't need get called for 'ralink,rt2880-reset').
Doing in this way ensures that 'CONFIG_OF' is not disabled anymore so the
above warning disapears.
Fixes: 6f3b15586eef ("clk: ralink: add clock and reset driver for MTMIPS SoCs")
Reported-by: kernel test robot <lkp@xxxxxxxxx>
Closes: https://lore.kernel.org/oe-kbuild-all/202307242310.CdOnd2py-lkp@xxxxxxxxx/
Suggested-by: Arnd Bergmann <arnd@xxxxxxxxxx>
Signed-off-by: Sergio Paracuellos <sergio.paracuellos@xxxxxxxxx>
---
Changes in v2:
- Merge two match tables into one to properly avoid this warning.
PATCH in v1: https://lore.kernel.org/lkml/20230802092647.3000666-1-sergio.paracuellos@xxxxxxxxx/T/
drivers/clk/ralink/clk-mtmips.c | 20 +++++---------------
1 file changed, 5 insertions(+), 15 deletions(-)
diff --git a/drivers/clk/ralink/clk-mtmips.c b/drivers/clk/ralink/clk-mtmips.c
index 1e7991439527..50a443bf79ec 100644
--- a/drivers/clk/ralink/clk-mtmips.c
+++ b/drivers/clk/ralink/clk-mtmips.c
@@ -821,6 +821,10 @@ static const struct mtmips_clk_data mt76x8_clk_data = {
};
static const struct of_device_id mtmips_of_match[] = {
+ {
+ .compatible = "ralink,rt2880-reset",
+ .data = NULL,
+ },
{
.compatible = "ralink,rt2880-sysc",
.data = &rt2880_clk_data,
@@ -1088,25 +1092,11 @@ static int mtmips_clk_probe(struct platform_device *pdev)
return 0;
}
-static const struct of_device_id mtmips_clk_of_match[] = {
- { .compatible = "ralink,rt2880-reset" },
- { .compatible = "ralink,rt2880-sysc" },
- { .compatible = "ralink,rt3050-sysc" },
- { .compatible = "ralink,rt3052-sysc" },
- { .compatible = "ralink,rt3352-sysc" },
- { .compatible = "ralink,rt3883-sysc" },
- { .compatible = "ralink,rt5350-sysc" },
- { .compatible = "ralink,mt7620-sysc" },
- { .compatible = "ralink,mt7628-sysc" },
- { .compatible = "ralink,mt7688-sysc" },
- {}
-};
-
static struct platform_driver mtmips_clk_driver = {
.probe = mtmips_clk_probe,
.driver = {
.name = "mtmips-clk",
- .of_match_table = mtmips_clk_of_match,
+ .of_match_table = mtmips_of_match,
},
};
--
2.25.1