Re: [PATCH v3 2/4] dt-bindings: net: Add Loongson-1 Ethernet Controller

From: Serge Semin
Date: Sun Aug 27 2023 - 17:02:33 EST


Hi Krzysztof

On Sun, Aug 27, 2023 at 09:56:06AM +0200, Krzysztof Kozlowski wrote:
> On 26/08/2023 23:04, Serge Semin wrote:
> >> + clock-names:
> >> + items:
> >> + - const: stmmaceth
> >
> > clock-names:
> > const: stmmaceth
> > ?
>

> The existing syntax is correct. This is a string array.

Could you please clarify whether it's a requirement (always specify
items: property for an array) or just an acceptable option (another
one is suggested in my comment)? I am asking because:
1. In this case the "clock-names" array is supposed to have only one
item. Directly setting "const: stmmaceth" with no items: property
shall simplify it.
2. There are single-entry "clock-names" property in the DT-bindings
defined as I suggested.
3. There is a "compatible" property which is also a string array but
it can be defined as I suggested (omitting the items property).

so based on all of that using the "items:"-based constraint here seems
redundant. Am I wrong to think like that? If so in what aspect?

-Serge(y)

>
> >
> >> +
> >> + interrupts:
> >> + maxItems: 1
> >> +
> >
> >> + interrupt-names:
> >> + items:
> >> + - const: macirq
> >
> > interrupt-names:
> > const: macirq
> > ?
>
> As well.
>
> >
> >> +
> >> + loongson,ls1-syscon:
> >> + $ref: /schemas/types.yaml#/definitions/phandle
> >> + description:
> >> + Phandle to the syscon containing some extra configurations
> >> + including PHY interface mode.
> >> +
> >
> >> + phy-mode:
> >> + items:
> >> + - enum:
> >> + - mii
> >> + - rmii
> >
> > phy-mode:
> > enum: ...
> > ?
>
> Here indeed, this is a string, not a list, so items are wrong.
>
>
>
> Best regards,
> Krzysztof
>