On 28/08/2023 21:18, Sricharan Ramabadhran wrote:
IPQ5018 has tsens v1.0 block with 4 sensors and 1 interrupt.
Signed-off-by: Sricharan Ramabadhran <quic_srichara@xxxxxxxxxxx>
---
.../bindings/thermal/qcom-tsens.yaml | 19 +++++++++++++++++++
1 file changed, 19 insertions(+)
diff --git a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
index 27e9e16e6455..2309bb6dce1b 100644
--- a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
+++ b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml
@@ -42,6 +42,7 @@ properties:
- qcom,msm8956-tsens
- qcom,msm8976-tsens
- qcom,qcs404-tsens
+ - qcom,ipq5018-tsens
This does not look like placed in alphanumeric order.
- const: qcom,tsens-v1
- description: v2 of TSENS
@@ -409,4 +410,22 @@ examples:
#qcom,sensors = <16>;
#thermal-sensor-cells = <1>;
};
+
+ - |
+ #include <dt-bindings/interrupt-controller/arm-gic.h>
+ // Example 5 (for any IPQ5018 based SoC-s):
No need for new example for a difference in compatible. Drop it.