Re: [PATCH v2 06/14] arm64: dts: qcom: sdm630: Drop RPM bus clocks

From: Krzysztof Kozlowski
Date: Wed Sep 13 2023 - 03:13:47 EST


On 12/09/2023 15:31, Konrad Dybcio wrote:
> These clocks are now handled from within the icc framework and are
> no longer registered from within the CCF. Remove them.
>
> Signed-off-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxx>
> ---
> arch/arm64/boot/dts/qcom/sdm630.dtsi | 49 +++++++-----------------------------
> 1 file changed, 9 insertions(+), 40 deletions(-)
>
> diff --git a/arch/arm64/boot/dts/qcom/sdm630.dtsi b/arch/arm64/boot/dts/qcom/sdm630.dtsi
> index ec6003212c4d..f11d2a07508c 100644
> --- a/arch/arm64/boot/dts/qcom/sdm630.dtsi
> +++ b/arch/arm64/boot/dts/qcom/sdm630.dtsi
> @@ -605,9 +605,6 @@ bimc: interconnect@1008000 {
> compatible = "qcom,sdm660-bimc";
> reg = <0x01008000 0x78000>;
> #interconnect-cells = <1>;
> - clock-names = "bus", "bus_a";
> - clocks = <&rpmcc RPM_SMD_BIMC_CLK>,
> - <&rpmcc RPM_SMD_BIMC_A_CLK>;

Bindings expect here two clocks, so you miss some bindings patches.

> };
>
> restart@10ac000 {
> @@ -619,28 +616,17 @@ cnoc: interconnect@1500000 {
> compatible = "qcom,sdm660-cnoc";
> reg = <0x01500000 0x10000>;
> #interconnect-cells = <1>;
> - clock-names = "bus", "bus_a";
> - clocks = <&rpmcc RPM_SMD_CNOC_CLK>,
> - <&rpmcc RPM_SMD_CNOC_A_CLK>;
> };
>
> snoc: interconnect@1626000 {
> compatible = "qcom,sdm660-snoc";
> reg = <0x01626000 0x7090>;
> #interconnect-cells = <1>;
> - clock-names = "bus", "bus_a";
> - clocks = <&rpmcc RPM_SMD_SNOC_CLK>,
> - <&rpmcc RPM_SMD_SNOC_A_CLK>;
> };
>
> anoc2_smmu: iommu@16c0000 {
> compatible = "qcom,sdm630-smmu-v2", "qcom,smmu-v2";
> reg = <0x016c0000 0x40000>;
> -
> - assigned-clocks = <&rpmcc RPM_SMD_AGGR2_NOC_CLK>;
> - assigned-clock-rates = <1000>;
> - clocks = <&rpmcc RPM_SMD_AGGR2_NOC_CLK>;
> - clock-names = "bus";

This is also against bindings. After your patch #4, such bus clock (or
other combinations) is still required.


> #global-interrupts = <2>;
> #iommu-cells = <1>;
>
> @@ -685,16 +671,12 @@ a2noc: interconnect@1704000 {
> compatible = "qcom,sdm660-a2noc";
> reg = <0x01704000 0xc100>;
> #interconnect-cells = <1>;
> - clock-names = "bus",
> - "bus_a",
> - "ipa",
> + clock-names = "ipa",

And which bindings does this match?

Best regards,
Krzysztof