Re: [PATCH V5 - RESEND 2/3] coresight: etm: Make cycle count threshold user configurable

From: Suzuki K Poulose
Date: Wed Sep 20 2023 - 05:22:42 EST


On 15/09/2023 10:36, Anshuman Khandual wrote:
Cycle counting is enabled, when requested and supported but with a default
threshold value ETM_CYC_THRESHOLD_DEFAULT i.e 0x100 getting into TRCCCCTLR,
representing the minimum interval between cycle count trace packets.

minor nit:

When Cycle counting is enabled, we use a default threshold value (0x100) for the instruction trace cycle counting.

This makes cycle threshold user configurable, from the user space via perf
event attributes. Although it falls back using ETM_CYC_THRESHOLD_DEFAULT,
in case no explicit request.

Minor nit:

This patch makes the cycle threshold user configurable via perf event
attributes( 'cc_threshold' => event->attr.config3[11:0] ), falling back
to the the current default if unspecified.



As expected it creates a sysfs file as well.



/sys/bus/event_source/devices/cs_etm/format/cc_threshold

New 'cc_threshold' uses 'event->attr.config3' as no more space is available
in 'event->attr.config1' or 'event->attr.config2'.

Trim the above part.


Rest looks fine to me.

Suzuki