[PATCH] thermal: core: Check correct temperature for thermal trip notification
From: Nícolas F. R. A. Prado
Date: Fri Sep 22 2023 - 15:27:35 EST
The thermal trip down notification should be triggered when the
temperature goes below the trip temperature minus the hysteresis. But
while the temperature is correctly checked against that, the last
temperature is instead compared against the trip point temperature. The
end result is that the notification won't always be triggered, only when
the temperature happens to drop quick enough so that the last
temperature was still above the trip point temperature.
Fix the incorrect check.
Fixes: 55cdf0a283b8 ("thermal: core: Add notifications call in the framework")
Signed-off-by: Nícolas F. R. A. Prado <nfraprado@xxxxxxxxxxxxx>
---
drivers/thermal/thermal_core.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/thermal/thermal_core.c b/drivers/thermal/thermal_core.c
index 58533ea75cd9..120fcf23b8e5 100644
--- a/drivers/thermal/thermal_core.c
+++ b/drivers/thermal/thermal_core.c
@@ -361,7 +361,7 @@ static void handle_thermal_trip(struct thermal_zone_device *tz, int trip_id)
tz->temperature >= trip.temperature)
thermal_notify_tz_trip_up(tz->id, trip_id,
tz->temperature);
- if (tz->last_temperature >= trip.temperature &&
+ if (tz->last_temperature >= (trip.temperature - trip.hysteresis) &&
tz->temperature < (trip.temperature - trip.hysteresis))
thermal_notify_tz_trip_down(tz->id, trip_id,
tz->temperature);
--
2.42.0