Re: [RFC PATCH v2 net-next 03/15] phy: ethernet: add configuration interface for copper backplane Ethernet PHYs
From: Simon Horman
Date: Mon Oct 02 2023 - 13:20:14 EST
On Mon, Oct 02, 2023 at 04:11:10PM +0300, Vladimir Oltean wrote:
> Hi Simon,
>
> On Thu, Sep 28, 2023 at 09:05:36PM +0200, Simon Horman wrote:
> > On Sat, Sep 23, 2023 at 04:48:52PM +0300, Vladimir Oltean wrote:
> >
> > ...
> >
> > > +/**
> > > + * coef_update_opposite - return the opposite of one C72 coefficient update
> > > + * request
> > > + *
> > > + * @update: original coefficient update
> > > + *
> > > + * Helper to transform the update request of one equalization tap into a
> > > + * request of the same tap in the opposite direction. May be used by C72
> > > + * phy remote TX link training algorithms.
> > > + */
> > > +static inline enum coef_update coef_update_opposite(enum coef_update update)
> >
> > Hi Vladimir,
> >
> > another nit from me.
> >
> > Please put the inline keyword first.
> > Likewise elsewhere in this patch.
> >
> > Tooling, including gcc-13 with W=1, complains about this.
>
> Thanks for pointing this out. I guess you are talking about the c72_coef_update_print()
> function, whose prototype is mistakenly "static void inline" instead of
> "static inline void". I cannot find the problem with the quoted coef_update_opposite().
Yes, you are right.
Sorry for my error.