Re: [PATCH v1 3/3] regulator: fixed: forward under-voltage events
From: Oleksij Rempel
Date: Tue Oct 10 2023 - 09:42:17 EST
On Tue, Oct 10, 2023 at 02:55:31PM +0200, Oleksij Rempel wrote:
> Hi,
>
> On Tue, Oct 10, 2023 at 01:19:36PM +0100, Mark Brown wrote:
> > On Tue, Oct 10, 2023 at 10:59:06AM +0200, Oleksij Rempel wrote:
> > > Add handler to forward under-voltage events.
> > > On systems for more or less complicated regulator chains we need to
> > > forward under-voltage events to actual driver which need to react on
> > > them.
> >
> > It isn't clear to me why this would be implemented in one specific
> > driver, nor why this would be done unconditionally. Could you provide
> > some information on the problem you're trying to solve here?
>
> The hardware I am working with has an under-voltage sensor on the 24V
> supply regulator and some backup capacitors to run SoC for 100ms. I want
> to forward under-voltage events across a chain of different regulators
> to a designated consumer. For instance, to the mmc driver, enabling it
> to initiate shutdown before power loss occurs. Additionally, a bit can
> be set in the volatile memory of a scratch pad in an RTC clock to record
> sudden power loss, which can be checked on the next system start.
The bit picture of my HW may potentially be even more advanced:
- some regulator chain paths are disabled by the HW. With other words
under-voltage event is converted to fail or disable. There is nothing
what software can do, but it will be good to reflect it on the SW
side for diagnostic.
- some paths can be disabled by software to get some more milliseconds
of life and complete emergency shutdown task.
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |