Re: [PATCH v4 09/17] staging: iio: resolver: ad2s1210: convert DOS overrange threshold to event attr

From: Jonathan Cameron
Date: Tue Oct 10 2023 - 11:55:18 EST


On Thu, 5 Oct 2023 19:50:26 -0500
David Lechner <dlechner@xxxxxxxxxxxx> wrote:

> The AD2S1210 has a programmable threshold for the degradation of signal
> (DOS) overrange fault. This fault is triggered when either the sine or
> cosine input rises above the threshold voltage.
>
> This patch converts the custom device DOS overrange threshold attribute
> to an event rising edge threshold attribute on the monitor signal
> channel.
>
> The attribute now uses millivolts instead of the raw register value in
> accordance with the IIO ABI.
>
> Emitting the event will be implemented in a later patch.
>
> Signed-off-by: David Lechner <dlechner@xxxxxxxxxxxx>
Applied