Re: [PATCH 1/3] ASoC: ti: omap-mcbsp: Ignore errors for getting fck_src

From: Andreas Kemnade
Date: Fri Oct 13 2023 - 07:25:20 EST


On Thu, 12 Oct 2023 17:41:34 +0300
Péter Ujfalusi <peter.ujfalusi@xxxxxxxxx> wrote:

> On 07/10/2023 10:11, Andreas Kemnade wrote:
> >> OK good to hear it works, I'll send out fixes for omap4 and 5, seems
> >> the runtime PM warning is something different.
> >>
> >>> omap-mcbsp 40124000.mcbsp: Runtime PM usage count underflow!
> >>> # cat /sys/bus/platform/devices/40124000.mcbsp/power/runtime_status
> >>> active
> >>>
> >>> even with no sound.
> >>
> > Well, it is a regression caused by your fix. Without it (and not reverting
> > the already applied ignore patch), runtime is properly suspended. Don't know
> > why yet.
>
> I guess it is because of the pm_runtime_put_sync() in the
> omap2_mcbsp_set_clks_src() around the fclk re-parenting.
> That is a bit dubious thing for sure. We need to disable the device to
> be able to re-parent the fclk but if we disable the device it is going
> to be powered down, right? I think we have appropriate context handling,
> so it might work, but it is certainly not a rock solid code... If you
> have a stream running already, you don't really want to kill the McBSP.
>
Ok, so if the device is powered of at omap2_mcbsp_set_clks_src()
we get the usage count underflow, and the counter is incremented
immediately again in the runtime put function. So things get out of balance...
I'll check Tony's fix here.

> The problem is that this mux is outside of the McBSP IP, so we need a
> system level (iow, clk API) way to change it runtime.
>
> What is the machine driver where this happens? If you set the sysclk in
> hw_params of the machine driver, it will be OK, but if you do that in
> probe time then it is likely going to fail as you experienced
>
As you see in the other patches of this series,
it is a simple-audio-card with a tlv320aic3x codec
in combination with the mcbsp.

Regards,