Hi Thinh,
On 10/13/2023 3:47 AM, Thinh Nguyen wrote:
On Fri, Oct 13, 2023, Krishna Kurapati PSSNV wrote:
On 10/12/2023 11:29 PM, Thinh Nguyen wrote:
Hi Thinh,-static int dwc3_gadget_soft_disconnect(struct dwc3 *dwc)
+int dwc3_gadget_soft_disconnect(struct dwc3 *dwc)
{
unsigned long flags;
int ret;
@@ -2701,7 +2701,7 @@ static int dwc3_gadget_soft_disconnect(struct dwc3 *dwc)
return ret;
}
-static int dwc3_gadget_soft_connect(struct dwc3 *dwc)
+int dwc3_gadget_soft_connect(struct dwc3 *dwc)
{
int ret;
@@ -3963,6 +3963,7 @@ static void dwc3_gadget_disconnect_interrupt(struct dwc3 *dwc)
dwc3_gadget_dctl_write_safe(dwc, reg);
dwc->connected = false;
+ dwc->cable_disconnected = true;
dwc3_disconnect_gadget(dwc);
@@ -4038,6 +4039,7 @@ static void dwc3_gadget_reset_interrupt(struct dwc3 *dwc)
*/
dwc3_stop_active_transfers(dwc);
dwc->connected = true;
+ dwc->cable_disconnected = false;
reg = dwc3_readl(dwc->regs, DWC3_DCTL);
reg &= ~DWC3_DCTL_TSTCTRL_MASK;
--
2.42.0
We can just reset the controller when there's End Transfer command
timeout as a failure recovery. No need to do what you're doing here.
That was what I initially wanted to do, but there were couple of reasons I
wanted to take this approach:
1. We can't just reset the controller in midst of gadget_interrupt. We need
to process it completely and then take action.
You can flag the driver so you can do the teardown/soft-reset at the
appropriate time.
2. The above log was seen on QRD variant of SM8550/SM8650 easily. But on
other platforms of same targets, the issue comes up at some other instances
of code, at a point where no IRQ is running. In such cases its not possible
to accurately find out code portions and reset the controller. The way I
confirmed that both platforms are having the same issue is:
a. During cable disconnect, I am not receiving disconnect interrupt
b. The reg dump is exactly same in both cases (BMU as well)
So I felt it was better to fix it during cable disconnect because even if we
remove cable, we are still in device mode only and in this case we can
unblock suspend and also bring back controller to a known state.
Let me know your thoughts on the above.
This issue happens outside of disconnect right? Did you account for port
reset?
The symptom should be the same. At some point, a command will be issued.
If a command timed out, then something is really wrong (especially End
Transfer command). We can attempt to recover base on this symptom then.
And you don't need to poll for timeout for this specific type of error.
Just read some known register like GSNPSID to see if it's invalid.
Hi Thinh,
Yes. It actually happens before disconnect, but I was trying to handle it during disconnect. How about I add a check in gadget_ep_cmd saying that if cmd timeout happens, then read the snpsid and if it reads an invalid value, then I will call soft_disconnect followed by soft_connect. That must cover all cases ?