Re: [PATCH v3 2/8] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll

From: Stephen Boyd
Date: Wed Oct 18 2023 - 19:59:51 EST


Quoting Varadarajan Narayanan (2023-10-18 02:29:15)
> The set rate and determine rate operations are different between
> Stromer and Stromer Plus PLLs. Hence, use stromer plus ops for
> ipq_pll_stromer_plus.

What goes wrong if we don't have this patch? Please add that detail to
the commit text.

>
> Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332")
> Signed-off-by: Kathiravan T <quic_kathirav@xxxxxxxxxxx>
> Signed-off-by: Varadarajan Narayanan <quic_varada@xxxxxxxxxxx>
> ---

Acked-by: Stephen Boyd <sboyd@xxxxxxxxxx>