Re: [PATCH v6 2/2] iio: pressure: driver for Honeywell HSC/SSC series

From: Andy Shevchenko
Date: Mon Dec 04 2023 - 07:57:45 EST


On Sat, Dec 02, 2023 at 06:06:24PM +0200, Petre Rodan wrote:
> On Thu, Nov 30, 2023 at 03:33:02PM +0200, Andy Shevchenko wrote:
> > On Wed, Nov 29, 2023 at 09:12:52PM +0200, Petre Rodan wrote:
> > > On Wed, Nov 29, 2023 at 07:24:31PM +0200, Andy Shevchenko wrote:
> > >
> > > 437: ret = device_property_read_string(dev, "honeywell,pressure-triplet",
> > > &triplet);
> > > [..]
> > > 455: ret = match_string(hsc_triplet_variants, HSC_VARIANTS_MAX,
> > > triplet);
> > > if (ret < 0)
> > > return dev_err_probe(dev, -EINVAL,
> > > "honeywell,pressure-triplet is invalid\n");
> > >
> > > hsc->pmin = hsc_range_config[ret].pmin;
> > > hsc->pmax = hsc_range_config[ret].pmax;
> > >
> > > triplet is got via device_property_read_string(), is there some other property
> > > function I should be using?
> >
> > I think I mentioned that API, but for your convenience
> > device_property_match_property_string().
>
> one of us is not sync-ed with 6.7.0-rc3 :)

No, one of us is not synced with subsystem "for-next", which in this case
is IIO "togreg" (IIRC) and it definitely has the above mentioned API.

--
With Best Regards,
Andy Shevchenko