Re: [PATCH] spi: stm32: use runtime PM to enable/disable controller
From: Alain Volmat
Date: Fri Dec 15 2023 - 13:28:14 EST
Hi,
sorry for the delay.
On Thu, Dec 14, 2023 at 10:58:54AM +0000, Mark Brown wrote:
> On Mon, Dec 04, 2023 at 03:20:55PM -0500, Ben Wolsieffer wrote:
> > Instead of disabling the SPI controller between each message, do it
> > as part of runtime PM.
>
> This doesn't apply against current code, please check and resend.
I rapidly gave a try on this patch on top of the spi/for-next branch
(manually fixing the conflict due to the MASTER->HOST renaming).
It turns out that with that applied, transfers on the MP13
(compatible: st,stm32h7-spi) are not working anymore while simply
removing it back it works again.
(test is simply doing loopback spidev_test)
spi mode: 0x0
bits per word: 8
max speed: 500000 Hz (500 kHz)
TX | 8D D6 73 8B 9D 8B 1C 7D 8D 80 EC 32 F9 0D BA AD 9F 88 A5 9B 3F AA 48 8C 21 35 0D C1 C8 E5 6A 81 |..s....}...2........?.H.!5....j.|
RX | 8D 00 00 00 D6 00 73 00 8B 00 00 00 9D 00 00 8B 1C 00 00 00 7D 00 00 8D F9 00 00 00 BA 00 00 00 |......s.............}...........|
The RX data contains lots of 00 between each byte. Moreover it seems
that with this patch applied non-dma transfer (when there is no dmas
properties within the node) are now failing.
I'll check that and give more details but could you avoid applying this
patch for the time being ?
Thanks.
Alain