Re: [PATCH v11 1/2] dt-bindings: adc: add AD7173
From: Rob Herring
Date: Mon Jan 08 2024 - 21:59:10 EST
On Wed, 20 Dec 2023 12:48:04 +0200, Dumitru Ceclan wrote:
> The AD7173 family offer a complete integrated Sigma-Delta ADC solution
> which can be used in high precision, low noise single channel applications
> or higher speed multiplexed applications. The Sigma-Delta ADC is intended
> primarily for measurement of signals close to DC but also delivers
> outstanding performance with input bandwidths out to ~10kHz.
>
> Signed-off-by: Dumitru Ceclan <mitrutzceclan@xxxxxxxxx>
> ---
> V10->V11
> - Fix example warning: '#gpio-cells' is a dependency of 'gpio-controller'
> - Add description to #gpio-cells property
> V9->V10
> - Fix dt_binding_check type warning from adi,reference-select
> V8->v9
> - Add gpio-controller and "#gpio-cells" properties
> - Add missing avdd2 and iovdd supplies
> - Add string type to reference-select
> V7->V8
> - include missing fix from V6
> V6->V7 <no changes>
> V5->V6
> - Moved global required property to proper placement
> V4 -> V5
> - Use string enum instead of integers for "adi,reference-select"
> - Fix conditional checking in regards to compatible
> V3 -> V4
> - include supply attributes
> - add channel attribute for selecting conversion reference
> V2 -> V3
> - remove redundant descriptions
> - use referenced 'bipolar' property
> - remove newlines from example
> V1 -> V2 <no changes>
>
> .../bindings/iio/adc/adi,ad7173.yaml | 188 ++++++++++++++++++
> 1 file changed, 188 insertions(+)
> create mode 100644 Documentation/devicetree/bindings/iio/adc/adi,ad7173.yaml
>
Reviewed-by: Rob Herring <robh@xxxxxxxxxx>