RE: [PATCH] thermal/drivers/qoriq: fix getting tmu range

From: Peng Fan
Date: Thu Jan 11 2024 - 05:47:28 EST


Hi Sascha,

> Subject: Re: [PATCH] thermal/drivers/qoriq: fix getting tmu range
>
> Hi Peng,
>
> On Fri, Oct 20, 2023 at 04:13:37PM +0800, Peng Fan (OSS) wrote:
> > From: Peng Fan <peng.fan@xxxxxxx>
> >
> > TMU Version 1 has 4 TTRCRs, while TMU Version >=2 has 16 TTRCRs.
> > So limit the len to 4 will report "invalid range data" for i.MX93.
> >
> > This patch drop the local array with allocated ttrcr array and able to
> > support larger tmu ranges.
> >
> > Fixes: f12d60c81fce ("thermal/drivers/qoriq: Support version 2.1")
> > Signed-off-by: Peng Fan <peng.fan@xxxxxxx>
> > ---
> > drivers/thermal/qoriq_thermal.c | 12 ++++++++----
> > 1 file changed, 8 insertions(+), 4 deletions(-)
> >
> > diff --git a/drivers/thermal/qoriq_thermal.c
> > b/drivers/thermal/qoriq_thermal.c index ccc2eea7f9f5..404f01cca4da
> > 100644
> > --- a/drivers/thermal/qoriq_thermal.c
> > +++ b/drivers/thermal/qoriq_thermal.c
> > @@ -57,6 +57,9 @@
> > #define REGS_TTRnCR(n) (0xf10 + 4 * (n)) /* Temperature Range n
> > * Control Register
> > */
> > +#define NUM_TTRCR_V1 4
> > +#define NUM_TTRCR_MAX 16
> > +
> > #define REGS_IPBRR(n) (0xbf8 + 4 * (n)) /* IP Block Revision
> > * Register n
> > */
> > @@ -71,6 +74,7 @@ struct qoriq_sensor {
> >
> > struct qoriq_tmu_data {
> > int ver;
> > + u32 ttrcr[NUM_TTRCR_MAX];
> > struct regmap *regmap;
> > struct clk *clk;
> > struct qoriq_sensor sensor[SITES_MAX];
> > @@ -182,17 +186,17 @@ static int qoriq_tmu_calibration(struct device
> *dev,
> > struct qoriq_tmu_data *data)
> > {
> > int i, val, len;
> > - u32 range[4];
>
> Why don't you keep the array locally on the stack? Will it be needed
> elsewhere later?

Because max 16 as of now, it will consume 64bytes in stack, so I
move it out.

>
> Other than that:
>
> Tested-by: Sascha Hauer <s.hauer@xxxxxxxxxxxxxx>
>

Thanks for testing this patch.

Thanks,
Peng.

> Would be great if this could be picked up anytime soon.
>
> Sascha
>
> --
> Pengutronix e.K. | |
> Steuerwalder Str. 21 |
> http://www.p/
> engutronix.de%2F&data=05%7C02%7Cpeng.fan%40nxp.com%7C227277d8c0
> 20468aaf6e08dc128ba2ab%7C686ea1d3bc2b4c6fa92cd99c5c301635%7C0%
> 7C0%7C638405638133353126%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC
> 4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000%
> 7C%7C%7C&sdata=ilwPz4Bs6f7CLf2snic7S%2FUsff0AYCgsFuZP9d2UExo%3D&
> reserved=0 |
> 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
> Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |