Re: [PATCH 1/3] dt-bindings: net: dp83826: add ti,cfg-dac-minus binding

From: Russell King (Oracle)
Date: Thu Jan 11 2024 - 11:52:38 EST


On Thu, Jan 11, 2024 at 04:45:26PM +0000, POPESCU Catalin wrote:
> On 11.01.24 17:35, Andrew Lunn wrote:
> > [You don't often get email from andrew@xxxxxxx. Learn why this is important at https://aka.ms/LearnAboutSenderIdentification ]
> >
> > This email is not from Hexagon’s Office 365 instance. Please be careful while clicking links, opening attachments, or replying to this email.
> >
> >
> > On Thu, Jan 11, 2024 at 05:19:25PM +0100, Catalin Popescu wrote:
> >> Add property ti,cfg-dac-minus to allow for voltage tuning
> >> of logical level -1 of the MLT-3 encoded data.
> >>
> >> Signed-off-by: Catalin Popescu <catalin.popescu@xxxxxxxxxxxxxxxxxxxx>
> >> ---
> >> Documentation/devicetree/bindings/net/ti,dp83822.yaml | 9 +++++++++
> >> 1 file changed, 9 insertions(+)
> >>
> >> diff --git a/Documentation/devicetree/bindings/net/ti,dp83822.yaml b/Documentation/devicetree/bindings/net/ti,dp83822.yaml
> >> index db74474207ed..2f010333be49 100644
> >> --- a/Documentation/devicetree/bindings/net/ti,dp83822.yaml
> >> +++ b/Documentation/devicetree/bindings/net/ti,dp83822.yaml
> >> @@ -62,6 +62,15 @@ properties:
> >> for the PHY. The internal delay for the PHY is fixed to 3.5ns relative
> >> to transmit data.
> >>
> >> + ti,cfg-dac-minus:
> >> + description: |
> >> + DP83826 PHY only.
> >> + Sets the voltage ratio of the logical level -1 for the MLT-3 encoded data.
> >> + 0 = 50%, 1 = 56.25%, 2 = 62.50%, 3 = 68.75%, 4 = 75%, 5 = 81.25%, 6 = 87.50%,
> >> + 7 = 93.75%, 8 = 100%, 9 = 106.25%, 10 = 112.50%, 11 = 118.75%, 12 = 125%,
> >> + 13 = 131.25%, 14 = 137.50%, 15 = 143.75%, 16 = 150%.
> >> + enum: [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16]
> > We try to avoid register values in DT. We use real units. This is a
> > voltage you are configuring, so can you change the unit to millivolts?
> > Have the driver do the conversion of volts to register value.
> >
> > Is it possible to configure any of the other logical levels?
>
> Hi Andrew,
> These are not raw register values and these are not voltage values but
> voltage ratios. I'm mapping the voltage ratios to enum values [0-16]
> which are converted to register raw values by the driver. I don't see a
> better way to do this.

enum: [ 5000, 5625, 6250, 6875, 7500, 8125, 8750, 9375, 10000,
10625, 11250, 11875, 12500 13125, 13750, 14375, 15000 ]

?

--
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/
FTTP is here! 80Mbps down 10Mbps up. Decent connectivity at last!