Re: [PATCH v7 2/4] dt-bindings: clock: sophgo: support SG2042

From: Chen Wang
Date: Thu Jan 11 2024 - 19:09:38 EST



On 2024/1/12 0:58, Conor Dooley wrote:
On Thu, Jan 11, 2024 at 04:00:04PM +0800, Chen Wang wrote:
hi,Conor,

There are four types of clocks for SG2042 and following are where their
control registers are defined in:

PLL:all in SYS_CTRL
DIV: all in CLOCK
GATE: some are in SYS_CTRL, some others are in CLOCK
When you say "some", do you meant some entire clocks are in SYS_CTRL and
some entire clocks are in the CLOCKS? Or do you meant that for a given
clock, some registers are in SYS_CTRL and some are in CLOCK? It's the
first option, right?

It's the first option.

MUX: all in CLOCK