Re: [PATCH] iio: humidity: hdc3020: fix temperature offset

From: Nuno Sá
Date: Thu Jan 25 2024 - 06:06:01 EST


Hi Dimitri,

On Thu, 2024-01-25 at 11:26 +0100, Dimitri Fedrau wrote:
> The temperature offset should be negative according to the datasheet.
> Adding a minus to the existing offset results in correct temperature
> calculations.
>
> Signed-off-by: Dimitri Fedrau <dima.fedrau@xxxxxxxxx>
> ---

This is a fix. You're missing a Fixes: tag in your commit message.
git log --grep="Fixes:" should give you some examples...

With that, feel free to add:

Reviewed-by: Nuno Sa <nuno.sa@xxxxxxxxxx>

>  drivers/iio/humidity/hdc3020.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/iio/humidity/hdc3020.c b/drivers/iio/humidity/hdc3020.c
> index 4e3311170725..ed70415512f6 100644
> --- a/drivers/iio/humidity/hdc3020.c
> +++ b/drivers/iio/humidity/hdc3020.c
> @@ -322,7 +322,7 @@ static int hdc3020_read_raw(struct iio_dev *indio_dev,
>   if (chan->type != IIO_TEMP)
>   return -EINVAL;
>  
> - *val = 16852;
> + *val = -16852;
>   return IIO_VAL_INT;
>  
>   default: