[PATCH v6 3/5] ABI: sysfs-class-hwmon: add descriptions for humidity min/max alarms
From: Javier Carrasco
Date: Tue Jan 30 2024 - 16:07:37 EST
This attributes have been recently introduced and require the
corresponding ABI documentation.
Signed-off-by: Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx>
---
Documentation/ABI/testing/sysfs-class-hwmon | 18 ++++++++++++++++++
1 file changed, 18 insertions(+)
diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon
index 3dac923c9b0e..8446e95f23b1 100644
--- a/Documentation/ABI/testing/sysfs-class-hwmon
+++ b/Documentation/ABI/testing/sysfs-class-hwmon
@@ -968,6 +968,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/humidityY_max_alarm
+Description:
+ Maximum humidity detection
+
+ - 0: OK
+ - 1: Maximum humidity detected
+
+ RO
+
What: /sys/class/hwmon/hwmonX/humidityY_max_hyst
Description:
Humidity hysteresis value for max limit.
@@ -987,6 +996,15 @@ Description:
RW
+What: /sys/class/hwmon/hwmonX/humidityY_min_alarm
+Description:
+ Minimum humidity detection
+
+ - 0: OK
+ - 1: Minimum humidity detected
+
+ RO
+
What: /sys/class/hwmon/hwmonX/humidityY_min_hyst
Description:
Humidity hysteresis value for min limit.
--
2.39.2