On 2/22/24 08:47, Andy Shevchenko wrote:
On Thu, Feb 22, 2024 at 06:43:08PM +0200, Andy Shevchenko wrote:
On Thu, Feb 22, 2024 at 03:23:24PM +0200, Andy Shevchenko wrote:
On Thu, Feb 22, 2024 at 11:07:05AM +1030, Andrew Jeffery wrote:
On Wed, 2024-02-21 at 20:31 +0200, Andy Shevchenko wrote:
Since we have now a common helper to read port properties
use it instead of sparse home grown solution.
I did some brief testing of the series for the Aspeed machines under
qemu, building them on top of v6.8-rc5:
export ARCH=arm
export CROSS_COMPILE=arm-linux-gnueabihf-
make aspeed_g5_defconfig
make -j$(nproc)
qemu-system-arm -M rainier-bmc -nographic -no-reboot -kernel arch/arm/boot/zImage -dtb arch/arm/boot/dts/aspeed/aspeed-bmc-ibm-rainier.dtb -initrd ...
I got an oops during boot, which bisected to this change:
Thank you for prompt testing! I will look at it.
I found the issue, will be fixed in next version.
Whoever is going to test this series, the
- port->iotype = use_defaults ? UPIO_MEM : port->iotype;
+ port->iotype = UPIO_MEM;
should be applied to uart_read_port_properties() implementation.
Thanks, on 8250_bcm7271.c with the above hunk applied, I did not spot any differences between the values returned by stty or a cat /sys/class/tty/ttyS0/* before or after, the console remained fully functional. I will see if I can run an additional test where I removed the DT's "clocks" property and confirm that the fall back to "clock-frequency" works.
Thanks Andy!