Re: [PATCH v2 2/3] drm/panel: panel-edp: Match edp_panels with panel name

From: Doug Anderson
Date: Wed Feb 28 2024 - 19:25:47 EST


Hi,

On Tue, Feb 27, 2024 at 5:11 PM Hsin-Yi Wang <hsinyi@xxxxxxxxxxxx> wrote:
>
> @@ -2107,13 +2113,41 @@ static const struct edp_panel_entry edp_panels[] = {
> { /* sentinal */ }
> };
>
> -static const struct edp_panel_entry *find_edp_panel(u32 panel_id)
> +static bool edid_has_name(struct edid *edid, const char *panel_name)
> +{
> + int i, j;
> + char buf[13];
> +

Should have some comment about why this can't use
drm_edid_get_monitor_name(). AKA because panels seem to be storing the
monitor name tagged as raw strings instead of as the name. Should
probably also have some of the other checks from
is_display_descriptor() like checking for clock of 0 and pad1 of 0.


> + for (i = 0; i < 4; i++) {

Instead of 4, I think this can be ARRAY_SIZE(edid->detailed_timings), right?


> + strncpy(buf, edid->detailed_timings[i].data.other_data.data.str.str,
> + sizeof(buf));

I can never quite remember which of the strXcpy() routines are frowned
upon and which are the golden children at the moment. ...but I don't
think we really need the copy nor the local buffer anyway, right?
You're already going through this thing 1 byte at a time so just
compare it straight away.


> + for (j = 0; j < 13; j++) {
> + if (buf[j] == 0x0a) {

Instead of hardcoding 0x0a, I think you want '\n', no?


> + buf[j] = '\0';
> + break;
> + }
> + }
> + buf[12] = '\0';
> + if (strncmp(panel_name, buf, strlen(panel_name)) == 0)
> + return true;

Untested, but I think with my suggestions above the function becomes this:

static bool edid_has_name(struct edid *edid, const char *panel_name)
{
int i, j;

/*
* We can't use drm_edid_get_monitor_name() since many eDP panels store
* their name as a raw string. We'll accept either a string or name
* match as long as the panel ID also matches.
*/
for (i = 0; i < ARRAY_SIZE(edid->detailed_timings); i++) {
struct detailed_timing *timing = &edid->detailed_timings[i];

if (timing->pixel_clock != 0 ||
timing->data.other_data.pad1 != 0 ||
(timing->data.other_data.type != EDID_DETAIL_MONITOR_NAME &&
timing->data.other_data.type != EDID_DETAIL_MONITOR_STRING))
continue;

for (j = 0; j < ARRAY_SIZE(timing->data.other_data.data.str.str); j++) {
const char *str = timing->data.other_data.data.str.str;

if (panel_name[j] == '\0') {
if (str[j] == '\0' || str[j] == '\n')
return true;
break;
}
}
if (j == ARRAY_SIZE(timing->data.other_data.data.str.str) &&
panel_name[j] == '\0')
return true;
}

return false;
}