Re: [PATCH 3/4] iio: pressure: Add timestamp and scan_masks for BMP280 driver
From: Vasileios Amoiridis
Date: Mon Mar 04 2024 - 13:51:15 EST
On Mon, Mar 04, 2024 at 01:47:47PM +0200, Andy Shevchenko wrote:
> On Sun, Mar 03, 2024 at 05:52:59PM +0100, Vasileios Amoiridis wrote:
> > The scan mask for the BME280 device which contains humidity
> > measurement needs to become different in order for the timestamp
> > to be able to work. Scan masks are added for different combinations
> > of measurements. The temperature measurement is needed for either
> > pressure or humidity measurements.
>
> ...
>
> > +enum bmp280_scan {
> > + BMP280_TEMP,
> > + BMP280_PRESS,
> > + BME280_HUMID,
> > +};
>
> Hmm... Why do we need to actually copy the IIO ones? Can't we use IIO ones
> directly (or in some way)?
>
What do you mean exactly by copying the IIO ones? These values are used as
indexes to enable channels in the avail_scan_masks below.
> ...
>
> > +static const unsigned long bmp280_avail_scan_masks[] = {
> > + BIT(BMP280_TEMP),
> > + BIT(BMP280_PRESS) | BIT(BMP280_TEMP),
> > + 0,
>
> No comma for the terminator line.
>
> > +};
>
> > +static const unsigned long bme280_avail_scan_masks[] = {
> > + BIT(BMP280_TEMP),
> > + BIT(BMP280_PRESS) | BIT(BMP280_TEMP),
> > + BIT(BME280_HUMID) | BIT(BMP280_TEMP),
> > + BIT(BME280_HUMID) | BIT(BMP280_PRESS) | BIT(BMP280_TEMP),
> > + 0,
>
> Ditto.
>
> > +};
>
> ...
>
> > const struct iio_chan_spec *channels;
> > int num_channels;
> > + const unsigned long *avail_scan_masks;
> > unsigned int start_up_time;
>
> Please, run `pahole` every time you are changing data structure layout.
> Here you efficiently wasted 8 bytes of memory AFAICS.
>
> --
> With Best Regards,