Re: [PATCH 1/2] dt-bindings: iio: health: maxim,max30102: add max30101
From: Jonathan Cameron
Date: Sun Mar 24 2024 - 09:41:39 EST
On Thu, 21 Mar 2024 19:33:48 +0100
Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx> wrote:
> The Maxim max30101 irs the replacement for the max30105, which is no
is
> longer recommended for future designs.
>
> The max30101 does not require new properties, and it can be described
> with the existing ones for the max30105.
>
> Signed-off-by: Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx>
> ---
> Documentation/devicetree/bindings/iio/health/maxim,max30102.yaml | 3 ++-
> 1 file changed, 2 insertions(+), 1 deletion(-)
>
> diff --git a/Documentation/devicetree/bindings/iio/health/maxim,max30102.yaml b/Documentation/devicetree/bindings/iio/health/maxim,max30102.yaml
> index c13c10c8d65d..0e455809340f 100644
> --- a/Documentation/devicetree/bindings/iio/health/maxim,max30102.yaml
> +++ b/Documentation/devicetree/bindings/iio/health/maxim,max30102.yaml
> @@ -4,7 +4,7 @@
> $id: http://devicetree.org/schemas/iio/health/maxim,max30102.yaml#
> $schema: http://devicetree.org/meta-schemas/core.yaml#
>
> -title: Maxim MAX30102 heart rate and pulse oximeter and MAX30105 particle-sensor
> +title: Maxim MAX30101/2 heart rate and pulse oximeter and MAX30105 particle-sensor
>
> maintainers:
> - Matt Ranostay <matt.ranostay@xxxxxxxxxxxx>
> @@ -12,6 +12,7 @@ maintainers:
> properties:
> compatible:
> enum:
> + - maxim,max30101
> - maxim,max30102
> - maxim,max30105
>
>