Re: [PATCH] Documentation: ABI: document in_temp_input file

From: Jonathan Cameron
Date: Sat Apr 06 2024 - 12:45:40 EST


On Sat, 06 Apr 2024 17:31:04 +0200
Luca Weiss <luca@xxxxxxxxx> wrote:

> For example the BMP280 barometric pressure sensor on Qualcomm
> MSM8974-based Nexus 5 smartphone exposes such file in sysfs.
> Document it.
>
> Signed-off-by: Luca Weiss <luca@xxxxxxxxx>

Hi Luca,

Applied with a note added on fixing the line above to not reuse X.
A good additional thing but needs mentioning in the commit message.

Thanks,

Jonathan

> ---
> Documentation/ABI/testing/sysfs-bus-iio | 3 ++-
> 1 file changed, 2 insertions(+), 1 deletion(-)
>
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
> index 2e6d5ebfd3c7..7cee78ad4108 100644
> --- a/Documentation/ABI/testing/sysfs-bus-iio
> +++ b/Documentation/ABI/testing/sysfs-bus-iio
> @@ -243,7 +243,8 @@ Description:
> less measurements. Units after application of scale and offset
> are milli degrees Celsius.
>
> -What: /sys/bus/iio/devices/iio:deviceX/in_tempX_input
> +What: /sys/bus/iio/devices/iio:deviceX/in_tempY_input
> +What: /sys/bus/iio/devices/iio:deviceX/in_temp_input
> KernelVersion: 2.6.38
> Contact: linux-iio@xxxxxxxxxxxxxxx
> Description:
>
> ---
> base-commit: 8568bb2ccc278f344e6ac44af6ed010a90aa88dc
> change-id: 20240406-in_temp_input-4505d7fafff8
>
> Best regards,