[PATCH v2 0/4] iio: pressure: dps310: support negative temperature values

From: Thomas Haemmerle
Date: Wed Apr 10 2024 - 06:38:02 EST


This patch set fixes the reading of negative temperatures (returned in
millidegree celsius). As this requires a change of the error handling
other functions are aligned with this.
In addition a small code simplification for reading the scale factors
for temperature and pressure is included.

---
Changes in v2:
- include fixes tag
- Split up patch
- introduce variables for intermediate results in functions
- simplify scale factor reading

Thomas Haemmerle (4):
iio: pressure: dps310: support negative temperature values
iio: pressure: dps310: introduce consistent error handling
iio: pressure: dps310: consistently check return value of
`regmap_read`
iio: pressure: dps310: simplify scale factor reading

drivers/iio/pressure/dps310.c | 138 +++++++++++++++++++---------------
1 file changed, 77 insertions(+), 61 deletions(-)


base-commit: 2c71fdf02a95b3dd425b42f28fd47fb2b1d22702
--
2.34.1