[PATCH v3 0/4] iio: pressure: dps310: support negative temperature values

From: Thomas Haemmerle
Date: Mon Apr 15 2024 - 06:51:33 EST


This patch set fixes the reading of negative temperatures (returned in
millidegree celsius). As this requires a change of the error handling
other functions are aligned with this.
In addition a small code simplification for reading the scale factors
for temperature and pressure is included.

---
Changes in v2:
- include fixes tag
- Split up patch
- introduce variables for intermediate results in functions
- simplify scale factor reading

Changes in v3:
- fix locking issues reported in https://lore.kernel.org/all/cbdafb33-fd3b-47ad-a678-83fa92475278@moroto.mountain/

Thomas Haemmerle (4):
iio: pressure: dps310: support negative temperature values
iio: pressure: dps310: introduce consistent error handling
iio: pressure: dps310: consistently check return value of
`regmap_read`
iio: pressure: dps310: simplify scale factor reading

drivers/iio/pressure/dps310.c | 138 +++++++++++++++++++---------------
1 file changed, 77 insertions(+), 61 deletions(-)


base-commit: 0bbac3facb5d6cc0171c45c9873a2dc96bea9680
--
2.34.1