Re: [PATCH net-next] net: phy: add wol config options in phy device
From: Andrew Lunn
Date: Thu May 02 2024 - 12:37:42 EST
> It would be good to hear exactly why its necessary for phylib to track
> this state, and why the PHY isn't retaining it.
I _think_ it is a hardware reset. The call path is probably:
mdio_bus_phy_resume():
phy_init_hw():
phy_device_reset()
mdio_device_reset()
But it would be good to get this confirmed.