Re: [PATCH] clk: qcom: apss-ipq-pll: remove 'config_ctl_hi_val' from Stromer pll configs
From: Gabor Juhos
Date: Mon May 13 2024 - 14:44:50 EST
2024. 05. 10. 18:25 keltezéssel, Kathiravan Thirumoorthy írta:
>
>
> On 5/10/2024 12:23 AM, Konrad Dybcio wrote:
>> On 9.05.2024 10:08 AM, Gabor Juhos wrote:
>>> Since the CONFIG_CTL register is only 32 bits wide in the Stromer
>>> and Stromer Plus PLLs , the 'config_ctl_hi_val' values from the
>>> IPQ5018 and IPQ5332 configurations are not used so remove those.
>>>
>>> No functional changes.
>>>
>>> Signed-off-by: Gabor Juhos <j4g8y7@xxxxxxxxx>
>>> ---
>>
>> Hm, it sounds suspicious that we'd have these settings then.. Could somebody from
>> QC please confirm that everything's alright here?
>
>
> I checked the HW doc and yes in both IPQ5018 and IPQ5332 CONFIG_CTL_U register
> is not implemented. I see offset of CONFIG_CTL_U register is removed in the
> change[1] by Gabor.
Thanks for confirming!
>
> Given that, should we also drop the pll_has_64bit_config() if block from
> clk_stromer_pll_configure function?
If we can be sure, that there will be no Stromer PLLs which implements that
register we can drop the check. Also, since the SUPPORTS_FSM_MODE flag is not
set for any of the Stromer (Plus) Plls supported currently, the related check
can be dropped as well.
However I would keep that as is for now. I'm planning to remove the
clk_stromer_pll_configure() function entirely but that needs a bunch of
preparatory patches which I'm working on at the moment.
>
> Nevertheless, for this patch
>
> Reviewed-by: Kathiravan Thirumoorthy <quic_kathirav@xxxxxxxxxxx>
Thank you!
Regards,
Gabor