Re: [PATCH v7 3/5] iio: pressure: bmp280: Generalize read_{temp,press,humid}() functions

From: Jonathan Cameron
Date: Sun May 19 2024 - 10:28:34 EST


On Mon, 13 May 2024 01:05:22 +0200
Vasileios Amoiridis <vassilisamir@xxxxxxxxx> wrote:

> Add the coefficients for the IIO standard units and the IIO value
> inside the chip_info structure.
>
> Move the calculations for the IIO unit compatibility from inside the
> read_{temp,press,humid}() functions and move them to the general
> read_raw() function.
>
> In this way, all the data for the calculation of the value are
> located in the chip_info structure of the respective sensor.
>
> Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
This had the earlier missing
int ret; in it, so needs some manual tweaking.

Applied.

Thanks,

Jonathan