Re: [PATCH 1/2] arm: dts: arm: Drop redundant fixed-factor clocks
From: Linus Walleij
Date: Wed May 29 2024 - 04:51:23 EST
On Tue, May 28, 2024 at 9:15 PM Rob Herring (Arm) <robh@xxxxxxxxxx> wrote:
> There's not much reason to have multiple fixed-factor-clock instances
> which are all the same factor and clock input. Drop the nodes, but keep
> the labels to minimize the changes and keep some distinction of the
> different clocks.
>
> Signed-off-by: Rob Herring (Arm) <robh@xxxxxxxxxx>
Reviewed-by: Linus Walleij <linus.walleij@xxxxxxxxxx>
Yours,
Linus Walleij