On 29/05/2024 16:01, Guenter Roeck wrote:
On 5/29/24 00:07, Krzysztof Kozlowski wrote:
On 29/05/2024 08:07, Amna Waseem wrote:
Add a property to the binding to configure the Alert Polarity.
Alert pin is asserted based on the value of Alert Polarity bit of
Mask/Enable register. It is by default 0 which means Alert pin is
configured to be active low. To configure it to active high, set
alert-polarity property value to 1.
Signed-off-by: Amna Waseem <Amna.Waseem@xxxxxxxx>
---
Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml | 9 +++++++++
1 file changed, 9 insertions(+)
diff --git a/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml b/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml
index df86c2c92037..a3f0fd71fcc6 100644
--- a/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml
+++ b/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml
@@ -66,6 +66,14 @@ properties:
description: phandle to the regulator that provides the VS supply typically
in range from 2.7 V to 5.5 V.
+ alert-polarity:
Missing vendor prefix.
Are you sure you want a vendor prefix here ? Reason for asking is that
many hardware monitoring chips have configurable alert or interrupt polarity,
only the name is different. Some examples are the JC42.4 standard ("event
polarity"), adt7410/adt7420 "interrupt polarity", MAX31827 ("alarm polarity"),
or DS1621 ("output polarity"). We even have a vendor property, "adi,alarm-pol",
used for MAX31827.
Hm, I just checked if this is already existing property, but indeed I
did not check other variants.
Indeed it could go to common properties - hwmon-common.yaml. But then
how about using strings (as I asked before...).