Re: [PATCH v1 17/17] iio: chemical: bme680: Refactorize reading functions

From: Vasileios Amoiridis
Date: Sun Jun 02 2024 - 15:53:30 EST


On Sun, Jun 02, 2024 at 02:04:05PM +0100, Jonathan Cameron wrote:
> On Mon, 27 May 2024 20:38:05 +0200
> Vasileios Amoiridis <vassilisamir@xxxxxxxxx> wrote:
>
> > The reading of the pressure and humidity value, requires an update
> > of the t_fine variable which happens by reading the temperature
> > value.
> >
> > So the bme680_read_{press/humid}() functions of the above sensors
> > are internally calling the equivalent bme680_read_temp() function
> > in order to update the t_fine value. By just looking at the code
> > this relation is a bit hidden and is not easy to understand why
> > those channels are not independent.
> >
> > This commit tries to clear these thing a bit by splitting the
> > bme680_{read/compensate}_{temp/press/humid}() to the following:
> >
> > i. bme680_read_{temp/press/humid}_adc(): read the raw value from
> > the sensor.
> >
> > ii. bme680_calc_t_fine(): calculate the t_fine variable.
> >
> > iii. bme680_get_t_fine(): get the t_fine variable.
> >
> > iv. bme680_compensate_{temp/press/humid}(): compensate the adc
> > values and return the calculated value.
> >
> > v. bme680_read_{temp/press/humid}(): combine calls of the
> > aforementioned functions to return the requested value.
> >
> > Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
> This and patches I didn't comment on (1-3, 6-9, 12, 15-17)
> all look good to me.
>
> Thanks,
>
> Jonathan

Hi Jonathan,

Thank you very much for the quick and thorough review, it is
always extremely helpful. I will check a bit more on the
alignment thing internally in the I2C and SPI busses and I
will wait for your answer as well.

Cheers,
Vasilis