Re: [PATCH 3/9] x86/mce: Increment MCP count only for timer calls
From: Yazen Ghannam
Date: Mon Jun 03 2024 - 10:22:41 EST
On 5/24/24 10:53 AM, Borislav Petkov wrote:
> On Thu, May 23, 2024 at 10:56:35AM -0500, Yazen Ghannam wrote:
>> MCP count is currently incremented for any call to machine_check_poll().
>> Therefore, the count includes calls from the timer, boot-time polling,
>> and interrupt handlers.
>>
>> Only increment the MCP count when called from the timer so as to avoid
>> double counting the interrupt handlers.
>
> Well, but, every time the function is called, we did poll the banks.
> Sure, the count is part of /proc/interrupts but we did poll the banks in
> those other cases too. So I think showing an accurate poll number is
> actually representing the truth, no matter where it is shown...
>
Okay, fair enough.
In this case, should we also increment the count in __mc_scan_banks()?
Thanks,
Yazen