[PATCH v2 17/19] iio: chemical: bme680: Remove redundant gas configuration

From: Vasileios Amoiridis
Date: Thu Jun 06 2024 - 17:29:17 EST


There is no need to explicitly configure the gas measurement
registers every time a gas measurement takes place. These are
initial configurations which are written in the beginning and
they are not changed throughout the lifetime of the driver.

If in the future, the device starts to support multiple
configuration profiles with variable heater duration and
heater temperature, then they could become members of
the ->read_avail().

Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
---
drivers/iio/chemical/bme680_core.c | 7 -------
1 file changed, 7 deletions(-)

diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
index 1cf375904b8d..76b96993120f 100644
--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -683,13 +683,6 @@ static int bme680_read_gas(struct bme680_data *data,
u16 adc_gas_res, gas_regs_val;
u8 gas_range;

- /* Set heater settings */
- ret = bme680_gas_config(data);
- if (ret < 0) {
- dev_err(dev, "failed to set gas config\n");
- return ret;
- }
-
/* set forced mode to trigger measurement */
ret = bme680_set_mode(data, true);
if (ret < 0)
--
2.25.1