Re: [PATCH v2 02/19] iio: chemical: bme680: Fix calibration data variable

From: Jonathan Cameron
Date: Sun Jun 09 2024 - 07:01:30 EST


On Thu, 6 Jun 2024 23:22:54 +0200
Vasileios Amoiridis <vassilisamir@xxxxxxxxx> wrote:

> According to the BME68x Sensor API [1], the h6 calibration
> data variable should be an unsigned integer of size 8.
>
> [1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L789
> Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor")
> Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
Applied to the fixes-togreg branch of iio.git and marked for stable.
> ---
> drivers/iio/chemical/bme680_core.c | 2 +-
> 1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
> index 2c40c13fe97a..812829841733 100644
> --- a/drivers/iio/chemical/bme680_core.c
> +++ b/drivers/iio/chemical/bme680_core.c
> @@ -38,7 +38,7 @@ struct bme680_calib {
> s8 par_h3;
> s8 par_h4;
> s8 par_h5;
> - s8 par_h6;
> + u8 par_h6;
> s8 par_h7;
> s8 par_gh1;
> s16 par_gh2;