Re: [PATCH v2 17/19] iio: chemical: bme680: Remove redundant gas configuration

From: Jonathan Cameron
Date: Sun Jun 09 2024 - 07:09:21 EST


On Thu, 6 Jun 2024 23:23:11 +0200
Vasileios Amoiridis <vassilisamir@xxxxxxxxx> wrote:

> There is no need to explicitly configure the gas measurement
> registers every time a gas measurement takes place. These are
> initial configurations which are written in the beginning and
> they are not changed throughout the lifetime of the driver.
>
> If in the future, the device starts to support multiple
> configuration profiles with variable heater duration and
> heater temperature, then they could become members of
> the ->read_avail().
Similar oddly short line wrap. Fix them all up for v3.

Thanks

Jonathan

>
> Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
> ---
> drivers/iio/chemical/bme680_core.c | 7 -------
> 1 file changed, 7 deletions(-)
>
> diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
> index 1cf375904b8d..76b96993120f 100644
> --- a/drivers/iio/chemical/bme680_core.c
> +++ b/drivers/iio/chemical/bme680_core.c
> @@ -683,13 +683,6 @@ static int bme680_read_gas(struct bme680_data *data,
> u16 adc_gas_res, gas_regs_val;
> u8 gas_range;
>
> - /* Set heater settings */
> - ret = bme680_gas_config(data);
> - if (ret < 0) {
> - dev_err(dev, "failed to set gas config\n");
> - return ret;
> - }
> -
> /* set forced mode to trigger measurement */
> ret = bme680_set_mode(data, true);
> if (ret < 0)