Re: [PATCH v4 1/8] dt-bindings: counter: Add new ti,am62-eqep compatible

From: Krzysztof Kozlowski
Date: Mon Jun 10 2024 - 10:58:41 EST


On 10/06/2024 16:46, Judith Mendez wrote:
> Add new compatible ti,am62-eqep for TI K3 devices. If a device
> uses this compatible, require power-domains property.
>
> Since there is only one functional and interface clock for eqep,
> clock-names is not really required, so removed from required
> section, make it optional for ti,am3352-eqep compatible, and
> update the example.
>

...


> interrupts = <79>;
> };
>
> + - |
> + #include <dt-bindings/interrupt-controller/irq.h>
> + #include <dt-bindings/interrupt-controller/arm-gic.h>
> + #include <dt-bindings/soc/ti,sci_pm_domain.h>
> +
> + bus {
> + #address-cells = <2>;
> + #size-cells = <2>;
> + eqep1: counter@23210000 {

No need for label

> + compatible = "ti,am62-eqep";
> + reg = <0x00 0x23210000 0x00 0x100>;
> + power-domains = <&k3_pds 60 TI_SCI_PD_EXCLUSIVE>;
> + clocks = <&k3_clks 60 0>;
> + interrupts = <GIC_SPI 117 IRQ_TYPE_EDGE_RISING>;
> + status = "disabled";

Drop... which also points to another comment - since this was no-op and
example is basically the same, then just don't add it. No point.

> + };
> + };
> ...

Best regards,
Krzysztof