Re: [RFT PATCH v2 2/3] hwmon: (spd5118) Use spd5118 specific read/write operations

From: Guenter Roeck
Date: Tue Jun 18 2024 - 17:09:12 EST


Hi Paul,

On 6/18/24 13:37, Paul Menzel wrote:
[ ... ]
Unfortunately, it still fails:

    $ git log --no-decorate --oneline -4
    7ddcff2d44ae3 hwmon: (spd5118) Add support for Renesas/ITD SPD5118 hub controllers
    e89136743324f hwmon: (spd5118) Use spd5118 specific read/write operations
    0fcc7279f0cc4 hwmon: (spd5118) Use regmap to implement paging
    801b6aad6fa7a hwmon: (spd5118) Add configuration option for auto-detection

    $ uname -r
    6.10.0-rc4.mx64.461-00050-g7ddcff2d44ae
    $ sudo bash -c 'echo 56000 > /sys/class/hwmon/hwmon3/temp1_max'
    bash: line 1: echo: write error: No such device or address


Now I am really baffled. I don't think we could do anything simpler
than that.

Please try
sudo i2cset -y -f 0 0x50 0x21 0x06

That should update the critical temperature from 85 degrees C
to 86 degrees C. If that doesn't work, we'll be really out of luck
with that controller (or at least I don't have an idea what else to try).

Thanks,