Re: [PATCH v2 2/2] powerpc: hotplug driver bridge support

From: Krishna Kumar
Date: Tue Jun 25 2024 - 08:11:06 EST



On 5/31/24 7:22 PM, Krishna Kumar wrote:
> On 5/31/24 16:14, Krishna Kumar wrote:
>> On 5/23/24 20:22, Krishna Kumar wrote:
>>> Hi Oliver,
>>>
>>> Thanks for your suggestions. Pls find my response:
>>>
>>> On 5/20/24 20:29, Oliver O'Halloran wrote:
>>>> On Fri, May 17, 2024 at 9:15 PM krishna kumar <krishnak@xxxxxxxxxxxxx> wrote:
>>>>>> Uh, if I'm reading this right it looks like your "slot" C5 is actually
>>>>>> the PCIe switch's internal bus which is definitely not hot pluggable.
>>>>> It's a hotplug slot. Please see the snippet below:
>>>>>
>>>>> :~$ sudo lspci -vvv -s 0004:02:00.0 | grep --color HotPlug
>>>>>           SltCap:    AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise-
>>>>> :~$
>>>>>
>>>>> :~$ sudo lspci -vvv -s 0004:02:01.0 | grep --color HotPlug
>>>>>          SltCap:    AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise-
>>>>> :~$
>>>>>
>>>>> :~$ sudo lspci -vvv -s 0004:02:02.0 | grep --color HotPlug
>>>>>          SltCap:    AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise-
>>>>> :~$
>>>>>
>>>>> :~$ sudo lspci -vvv -s 0004:02:03.0 | grep --color HotPlug
>>>>>          SltCap:    AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise-
>>>>> :~$
>>>> All this is showing is that the switch downstream ports on bus 0004:02
>>>> have a slot capability. I already know that (see what I said
>>>> previously about physical links). The fact the downstream ports have a
>>>> slot capability also has absolutely nothing to do with anything I was
>>>> saying. Look at the lspci output for 0004:01:00.0 which is the
>>>> switch's upstream port. The upstream port device will not have a slot
>>>> capability because it's a bridge into the virtual PCI bus that is
>>>> internal to the switch.
>>> Let me try to understand your suggestion and what needs to be done now:
>>>
>>> lspci -nn snippet in current scenario:
>>>
>>> 0004:01:00.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052]
>>> 0004:01:00.1 Memory controller [0580]: PMC-Sierra Inc. Device [11f8:4052]
>>> 0004:02:00.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052]
>>> 0004:02:01.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052]
>>> 0004:02:02.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052]
>>> 0004:02:03.0 PCI bridge [0604]: PMC-Sierra Inc. Device [11f8:4052]
>>>
>>> lspci -tv snippet in current scenario:
>>>
>>> +-[0001:00]---00.0-[01-0a]--+-00.0-[02-0a]--+-00.0-[03-07]--
>>>  |                           |               +-01.0-[08]--+-00.0  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>>  |                           |               |            +-00.1  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>>  |                           |               |            +-00.2  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>>  |                           |               |            \-00.3  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>>  |                           |               +-02.0-[09]----00.0  Broadcom / LSI SAS3216 PCI-Express Fusion-MPT SAS-3
>>>  |                           |               \-03.0-[0a]----00.0  IBM PCI-E IPR SAS Adapter (ASIC)
>>>  |                           \-00.1  PMC-Sierra Inc. Device 4052
>>>
>>> C5 bus address:
>>>
>>> [root@ltczzess2-lp1 ~]# cat /sys/bus/pci/slots/C5/address
>>> 0004:02:00
>>> [root@ltczzess2-lp1 ~]#
>>>
>>> 0004:01:00.0 doesn't have hotplug capability but 0004:02:00.0 does
>>> have this capability. Below snippet tells about this:
>>>
>>> [root@ltczzess2-lp1 ~]# sudo lspci -vvv -s 0004:01:00.0 | grep --color HotPlug
>>> [root@ltczzess2-lp1 ~]#
>>> [root@ltczzess2-lp1 ~]# sudo lspci -vvv -s 0004:02:00.0 | grep --color HotPlug
>>>         SltCap:    AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise-
>>> [root@ltczzess2-lp1 ~]#
>>>
>>> In Function -  pnv_php_register_one() is responsible for slot creation from
>>> hotplug capable device node:
>>>
>>> Below is the current code that does check the device node for hot plug
>>> capability and takes the decision
>>>
>>>  /* Check if it's hotpluggable slot */
>>>         ret = of_property_read_u32(dn, "ibm,slot-pluggable", &prop32);
>>>         if (ret || !prop32){
>>>                 return -ENXIO;
>>>         }
>>>
>>> Its obvious that 0004:01:00.0 does not get above criteria fulfilled but
>>> 0004:02:00.0 does, so is the current behavior (Upstream port is not became
>>> C5 slot but downstream port became C5 slot).
>>>
>>> I am summarizing your suggested changes. Please let
>>> me know if I've got it right:
>>>
>>> 1. Do you want me to modify the code so that the C5
>>> device-bdf and bus-address become 0004:01:00/0004:01
>>> instead of 0004:02:00/0004:01?
>>>
>>> 2. When performing a hot-unplug operation on C5,
>>> should all devices from 0004:01 be removed? And
>>> should all devices from 0004:02 also be removed?
>>> I think the answer is yes, but please confirm.
>>>
>>> 3. When performing a hot-plug operation on C5,
>>> should all the devices removed earlier from 0004:01
>>>  and 0004:02 be re-attached?
>>>
>>> 4. Will there be any PCIe topology changes in this workflow?
>>>
>>> Once you confirm the above requirements, we can discuss
>>> how to proceed further.
>>> I have some follow up questions from your last mail and I am
>>> putting these questions in below paragraphs as inline statements.
>>> It will confirm me if we should do above things or not.
>>>
>>>
>>>>> It seems like your explanation about the missing 0004:01:00.0 may be
>>>>> correct and could be due to a firmware bug. However, the scope of this
>>>>> patch does not relate to this issue. Additionally, if it starts with
>>>>> 0004:01:00.0 to 0004:01:03.0, the behavior of hot-unplug and hot-plug
>>>>> operations will remain inconsistent. This patch aims to address the
>>>>> inconsistent behavior of hot-unplug and hot-plug.
>>>>>
>>>>> *snip*
>>>>>
>>>>>> It might be worth adding some logic to pnv_php to verify the PCI
>>>>>> bridge upstream of the slot actually has the PCIe slot capability to
>>>>>> guard against this problem.
>>>>> We can have a look at this problem in another patch.
>>>> The point of this series is to fix the behaviour of pnv_php, is it
>>>> not?
>>> Yes and we will do necessary things.
>>>
>>>> Powering off a PCI(e) slot is supposed to render it safe to
>>>> remove the card  in that slot.
>>> Do you mean physical-removal of the device after power-off ?
>>>
>>>>   Currently if you "power off" C5, the
>>>> kernel is still going to have active references to the switch's
>>>> upstream port device (at 0004:01:00.0) and the switch management
>>>> function (at 0004:01:00.1).
>>> Yes, since we are only operating on the downstream port of C5,
>>> upstream ports' reference to the kernel will remain the same.
>>>
>>>> If the kernel has active references to PCI
>>>> devices physically located in the slot we supposedly powered off, then
>>>> the hotplug driver isn't doing its job.
>>> We have only powered off the downstream ports, not the upstream port.
>>> The upstream port will remain powered on. Do you mean to say that it
>>> will cause a problem if we physically remove the device while the
>>> upstream port is powered on and the downstream port is powered off?
>>> Will it cause a kernel crash? Is this the reason for designating the
>>> upstream port as a C5 slot and performing a hot-plug operation on it?
>>> Is it correct to select a device port that is not hot-pluggable,
>>> designate it as a C5 slot, and perform a hot-plug operation on it?
>>>
>>>
>>>> The asymmetry between hot add
>>>> and removal that you're trying to fix here is a side effect of the
>>>> fact that pnv_php is advertising the wrong thing as a slot.
>>> Pnv-php is displaying the information, what it receives from the
>>> device node property. We will attempt to modify the code
>>> path that is responsible for this. I am not sure yet what
>>> additional code is needed for this, but I will figure it
>>> out. Is it okay to change this code?
>>>
>>>>   I think
>>>> you should stop pnv_php from advertising something as a slot when it's
>>>> not actually a slot because that's the root of all your problems.
>>> Okay, I am aligned but need some more clarification. Currently,
>>> we are observing this behavior with the PMC-Sierra bridge.
>>> Will this behavior occur with all bridges? In other words,
>>> will the upstream port capability not be hot-pluggable for
>>> all bridges and switches, and therefore not be considered
>>> for slot selection?
>>>
>>> In a previous email, you mentioned that this problem is due
>>> to a firmware bug, causing the driver to behave incorrectly
>>> and advertise the wrong port as a slot. Assuming the firmware
>>> bug is not present, what will be the behavior? Will there be
>>> any expected PCI-topology changes in the above "lspci -tv"
>>> command? Also, if the firmware bug is not present, do we still
>>> need to make changes to the driver code?
>>>
>>>
>>> Best Regards,
>>> Krishna
>> While I am still waiting for a response on the above points,
>> I would like to add a few more points here:
>>
>> 1. The connection between the upstream and downstream
>> ports is vendor-specific, and we cannot control this.
>>
>> 2. When running "lspci -vvv" on the upstream port, it neither
>> shows its a slot nor a hotplug slot. This is the reason pnv_php
>> does not advertise the upstream port as a slot. I have observed
>> similar behavior for upstream and downstream ports on other
>> architectures and with other switches as well.
>>
>>
>> Snippet for Upstream Port, showing it is neither a slot nor a hotplug
>> slot.
>>
>> # lspci -vvv -s 0004:01:00.0 | grep -i slot
>>             ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ SlotPowerLimit 0.000W
>>             TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt-
>> [root@ltczzess2-lp1 ~]#
>>
>> # lspci -vvv -s 0004:01:00.0 | grep -i Upstream
>>     Capabilities: [40] Express (v2) Upstream Port, MSI 00
>>              Retimer- 2Retimers- CrosslinkRes: Upstream Port
>>         ACSCap:    SrcValid- TransBlk- ReqRedir+ CmpltRedir+ UpstreamFwd- EgressCtrl- DirectTrans+
>>         ACSCtl:    SrcValid- TransBlk- ReqRedir- CmpltRedir- UpstreamFwd- EgressCtrl- DirectTrans-
>> #
>>
>> Downstream Port snippet : Its a slot and hotplug slot too.
>>
>> #
>> # lspci -vvv -s 0004:02:00.0 | grep -i slot
>>     Physical Slot: C5
>>     Capabilities: [40] Express (v2) Downstream Port (Slot+), MSI 00
>>             TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt-
>>             Slot #1, PowerLimit 0.000W; Interlock- NoCompl+
>> #
>>
>> # lspci -vvv -s 0004:02:00.0 | grep -i hot
>>         SltCap:    AttnBtn- PwrCtrl+ MRL- AttnInd- PwrInd- HotPlug+ Surprise-
>>         Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+)
>> #
>>
>> 3. The devices are connected to the downstream port, and hotplug
>> operations should only occur on these ports, not on the upstream port.
>>
>> 4. The upstream port and downstream port remain on different buses.
>> I have observed this behavior with other architectures and switches too.
>>
>> 5. Performing a poweroff operation on different ports of the bridge
>> and the devices behind them does not cause any problems for the
>> available upstream port. I have not encountered any tests/scenarios
>> where this could create a problem.
>>
>> Taking all of the above points into consideration, I do not see any need
>> for further code changes in the pnv_php driver regarding this matter.
>>
>>
> I got one more setup having below configuration. I did some experiment
> and here are my observations -
>
> # lspci -tv
>  +-[0033:00]---00.0-[01-17]----00.0-[02-17]--+-01.0-[03-07]--
>  |                                           +-04.0-[08-0c]--
>  |                                           +-05.0-[0d]----00.0  Samsung Electronics Co Ltd NVMe SSD Controller PM173X
>  |                                           +-06.0-[0e-12]--
>  |                                           \-07.0-[13-17]--
> # lspci -vvv -s 0033:01:00.0 | grep -i slot
>     Physical Slot: WIO Slot3-1
>             ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ SlotPowerLimit 75.000W
>             TrErr- Train- SlotClk- DLActive- BWMgmt- ABWMgmt-
>         VC0:    Caps:    PATOffset=03 MaxTimeSlots=1 RejSnoopTrans-
> [root@ltc-boston11 ~]#
> [root@ltc-boston11 ~]# lspci -vvv -s 0033:01:00.0 | grep -i Upstream
>     Capabilities: [68] Express (v2) Upstream Port, MSI 00
> [root@ltc-boston11 ~]#
> [root@ltc-boston11 ~]#
> [root@ltc-boston11 ~]# lspci -vvv -s 0033:01:00.0 | grep -i hot
>         Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+)
> [root@ltc-boston11 ~]#
>
> [root@ltc-boston11 ~]# lspci -nn | grep 0033
> 0033:00:00.0 PCI bridge [0604]: IBM POWER9 Host Bridge (PHB4) [1014:04c1]
> 0033:01:00.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa)
> 0033:02:01.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa)
> 0033:02:04.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa)
> 0033:02:05.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa)
> 0033:02:06.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa)
> 0033:02:07.0 PCI bridge [0604]: PLX Technology, Inc. PEX 9733 33-lane, 9-port PCI Express Gen 3 (8.0 GT/s) Switch [10b5:9733] (rev aa)
> 0033:0d:00.0 Non-Volatile memory controller [0108]: Samsung Electronics Co Ltd NVMe SSD Controller PM173X [144d:a824]
>
> [root@ltc-boston11 ~]#  cat /sys/bus/pci/slots/WIO\ Slot3-1/address
> 0033:01:00
>
> Hot-Unplug from above upstream port :
>
> # echo 0 > /sys/bus/pci/slots/WIO\ Slot3-1/power
> # lspci -tv
>  +-[0033:00]---00.0-[01-17]--
>  
>
> Hot-plug from above upstream port :
>
> [root@ltc-boston11 ~]# echo 1 > /sys/bus/pci/slots/WIO\ Slot3-1/power
> [root@ltc-boston11 ~]#
> [root@ltc-boston11 ~]#
> [root@ltc-boston11 ~]#
> [root@ltc-boston11 ~]# lspci -tv
>  +-[0033:00]---00.0-[01-17]----00.0-[02-17]--+-01.0-[03-07]--
>  |                                           +-04.0-[08-0c]--
>  |                                           +-05.0-[0d]----00.0  Samsung Electronics Co Ltd NVMe SSD Controller PM173X
>  |                                           +-06.0-[0e-12]--
>  |                                           \-07.0-[13-17]--
>
>
> What I want to say from above experiment is - if the upstream port is
> having the slot capability, pnv_php driver is able to do hot-plug/unplug
> operation on this.
>
> In our older case the upstream-port doesn't have slot capability, so there
> is no point of having hot-plug operation on this.
>
> Do you want to change the code logic to consider upstream-port always a slot? Is it even possible
> if lspci doesn't advertise it as a slot ?
>
>
> Best Regards,
>
> Krishna

I have uploaded patch version 3, and removed the DPC keyword from it. Did not do any
change in upstream port logic since driver does take care of this if the upstream port is
having slot property (explained above). 

Also I have left the check removal, since if I remove the check, the initialization for
non-bridge-port (i.e. for End-point) device happens multiple times (Verified with a nic card
having 4 ports). I have explained it below too.

It has been a while and I think we can merge this patch into mainline. I request to give
+1 on this.

These patch set will help Raptor Engineering team as well. They have done the testing with
these patch set. Two of the 3 bugs will be fixed by these patch set. And I am working towards
adding the NVME hot-plug support in this driver. At present link retraining does not happen
due to missing DPC support.

Best Regards,

Krishna


>
>
>>>>> We wanted to handle the more generic case and did not want to be confined to
>>>>> only one device assumption. We want to fix the current inconsistent behavior
>>>>> more generically.
>>>> Right, as I said above I don't think handing the more generic case is
>>>> actually required if pnv_php is doing its job properly. It doesn't
>>>> hurt though.
>>>>
>>>>> Regarding the fix, the fix is obvious:
>>>> really?
>>>>
>>>>> We have to traverse
>>>>> and find the bridge ports from DT and invoke  pci_scan_slot() on them. This will
>>>>> discover and create the entry for bridge ports (0004:02:00.0 to 0004:02:00.3 on
>>>>> the given bus- 0004:02). There is already an existing function, pci_scan_bridge()
>>>>> which is doing invocation of pci_scan_slot () for the devices behind the bridge,
>>>>> in this case for  SAS device. So eventually, we are doing a scan of all the entities
>>>>> behind the slot.
>>>> I already read your patch so I'm not sure why you feel the need to
>>>> re-describe it in tedious detail.
>>>>
>>>>> Would you like me to combine the non-bridge and bridge cases into one? I can attempt
>>>>> to do this. Hopefully, if we incorporate the iterate sibling logic case correctly,
>>>>> we may not need to maintain these two separate cases for bridge and non-bridge. I
>>>>> will attempt this, and if it works, I will include it in the next patch. Thanks.
>>>> Yes, do that.
>> A single call of pci_scan_slot is sufficient to power on the devices in the scenario
>> with multiple ports on the same card. However, it is not enough for a switch
>> containing multiple ports. If the check is removed and we rely on the logic to
>> traverse all the sibling device nodes and invoke pci_scan_slot() on each, in
>> this case, device initialization of NIC ports (represented below) in terms of bar region
>> and so will occur multiple times. Although this is not a problem and it works fine, we
>> have to make a choice whether to proceed with or without the check.
>>
>>
>> Snippet showing multiple port from a single card. This is not on bridge but on same
>> card.
>>
>> +-[0001:00]---00.0-[01-0a]--+-00.0-[02-0a]--+-00.0-[03-07]--
>>  |                           |               +-01.0-[08]--+-00.0  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>  |                           |               |                    +-00.1  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>  |                           |               |                    +-00.2  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>  |                           |               |                     \-00.3  Broadcom Inc. and subsidiaries NetXtreme BCM5719 Gigabit Ethernet PCIe
>>  |                           |               +-02.0-[09]----00.0  Broadcom / LSI SAS3216 PCI-Express Fusion-MPT SAS-3
>>  |                           |               \-03.0-[0a]----00.0  IBM PCI-E IPR SAS Adapter (ASIC)
>>  |                           \-00.1  PMC-Sierra Inc. Device 4052
>>
>>
>> Best regards,
>> Krishna
>>
>>
>>>> Also, do not post HTML emails to linux development lists. It breaks
>>>> plain text inline quoting which makes your messages annoying to reply
>>>> to. Some linux development lists will also silently drop HTML emails.
>>>> Please talk to the other LTC engineers about how to set up your mail
>>>> client to send plain text emails to avoid these problems in the
>>>> future.
>>>>
>>>> Oliver